SELECTED ION FLOW TUBE MASS SPECTROMETRY
Agency: | NATIONAL AERONAUTICS AND SPACE ADMINISTRATION |
---|---|
Level of Government: | Federal |
Category: |
|
Opps ID: | NBD00159036186785918 |
Posted Date: | Nov 30, 2022 |
Due Date: | Dec 9, 2022 |
Solicitation No: | 80MSFC230004 |
Source: | https://sam.gov/opp/b549a9ef1e... |
Procurement Technical Assistance Centers (PTACs) are an official government contracting resource for small businesses. Find your local PTAC (opens in new window) for free government expertise related to contract opportunities.
- Contract Opportunity Type: Combined Synopsis/Solicitation (Updated)
- All Dates/Times are: (UTC-06:00) CENTRAL STANDARD TIME, CHICAGO, USA
- Updated Published Date: Nov 30, 2022 10:39 am CST
- Original Published Date: Nov 21, 2022 04:58 pm CST
- Updated Date Offers Due: Dec 09, 2022 04:30 pm CST
- Original Date Offers Due: Dec 02, 2022 04:30 pm CST
- Inactive Policy: 15 days after date offers due
- Updated Inactive Date: Dec 24, 2022
- Original Inactive Date: Dec 17, 2022
-
Initiative:
- None
- Original Set Aside:
- Product Service Code: 6665 - HAZARD-DETECTING INSTRUMENTS AND APPARATUS
-
NAICS Code:
- 334516 - Analytical Laboratory Instrument Manufacturing
-
Place of Performance:
Huntsville , AL 35812USA
NASA/MSFC has a requirement for one (1) Selected Ion Flow Tube Spectrometer that meets the following specifications:
•Start-up time:
•Reagent ions: H30+, NO+,O2+
•Mass Range: 10 –400Da
•Mass resolution: unit mass resolution throughout the mass range
•Linearity range: Up to 6 orders of magnitude
•Dynamic range: Up to 6 orders of magnitude
•Live data streaming via ethernet port
•Generic spreadsheet format (CSV)
•Test format system information and raw data
•Summary Report generation
•Ambient operating humidity: 5 to 95%
•LCD touchscreen interface
•Remote control by MODBUS TCP or Syft protocol
•USB port including support for barcode scanner or keyboard (optional)
•230 VAC, 50-60Hz
•Carrier gas consumption: Helium 360sccm or Nitrogen180sccm
•Reagent ions: H30+, NO+,O2+
•Mass Range: 10 –400Da
•Mass resolution: unit mass resolution throughout the mass range
•Linearity range: Up to 6 orders of magnitude
•Dynamic range: Up to 6 orders of magnitude
•Live da/or services.
- One (1) year support
- HUNTSVILLE AL 35812
- HUNTSVILLE , AL 35812
- USA
- Glenda Clemons
- glenda.m.clemons@nasa.gov
- Nov 30, 2022 10:39 am CSTCombined Synopsis/Solicitation (Updated)
- Nov 21, 2022 04:58 pm CST Combined Synopsis/Solicitation (Original)
TRY FOR FREE
Not a USAOPPS Member Yet?
Get unlimited access to thousands of active local, state and federal government bids and awards in All 50 States.